Problem: If at
3
campground, what kind of Amp Service is used
-
15,
30
or
50?
Suggestion: Our Motor Home shore power cords are designed for
30
Amp service.
Problem: Batteries will not hold charge
Suggestion: Check the water levels. Deep Cycle Batteries need a
charge if they go dead;
a
3
Amp trickle for
2
or 3 days.
A
higher Amp charging rate will only give the battery a surface
charge that will not hold.
Problem: The house battery goes dead.
Suggestion: The battery may not be charging from the engine alternator. Check the fuse in the
power distribution panel (See Ford Owners Manual). Check the water levels in the batteries.
Problem: Furnace does not run overnight.
Suggestion: The batteries are low. The Furnace and Refrigerator are the two biggest draws on
the battery system.
Problem: The furnace is inoperable.
Suggestion:
1)
Low batteries. 2) The furnace fan has to run at a pre-set RPM before the gas
valve will open and allow the furnace to light.
3)
Check the heat vents to make sure the
"butterflies" are open. Closed vents can cause low
RPM's.
Problem: The furnace blows cold air.
Suggestion: 1) Check the
LP
bottle to make sure that it is on. 2) Check the thermostat for the
temperature setting. 3) Check the butterflies in the heat vents to make sure that they are open all
the way.
Problem: Will not switch from generator to shore power.
Suggestion: There is a built-in transfer switch on the converter that performs this function. This
would need to be checked by a Service Center.
Problem:
The Generator will not start.
Suggestion: The Generator is wired to the house batteries. The batteries may be low enough
that the Generator will not start. Start the motorhome and try starting the Generator. Check the
80
Amp
Breaker located on the passenger side of the firewall (not on all models).
Problem: The Generator rattles when running.
Suggestion:
1)
Check the exhaust pipe to see if
it
is loose.
2)
The fuel line may be sucking air.
Page view 52